CHIAWANG佳王MBR-02-P2-K-20 減壓閥 MBR-02-P1-K-20
引起壓力繼電器的誤操作的油路故障分析
圖6所示液壓系統(tǒng) 回路中,液壓缸節(jié)流閥裝在進油路上,爲進油節(jié)流調(diào)速回路。壓力繼電器YJ裝在缸7前端。該系統(tǒng)工作原理是:當缸右行到底時,右腔壓力升高達到壓力繼電器設定值后發(fā)出信號使DT2得電,DT1失電,液壓缸返回。
(1)故障現(xiàn)象:壓力繼電器在液壓缸右行未到底時,卻提前發(fā)信號。
(2)故障原因:可能由于外負載的變化引起壓力波動值超過壓力繼電器的調(diào)定值而引起誤動作。應檢查壓力繼電器與溢流閥的調(diào)定值,使壓力繼電器的設定值高于液壓缸的工作壓力0.3 MPa;溢流閥的調(diào)定壓力比壓力繼電器高0.3—0.6MPa。從而避免壓力波動引起壓力繼電器的誤操作。
VSV08-20-D2 VSV10-20-D2 VSE12-33-D2 VSV08-20-D2 VSV10-20-D2
DCG-02G-2B2-Y-10/20-NO/NC DCG-03G-2B2-Y-10/20-NO/NC
WE-2B2-02G-A2-30 WE-2B2-02G-A115-30 WE-2B2-02G-D2-30 WE-2B2-02G-A2-20 WE-2B2-02G-A115-20
WE-2B2-02G-D2-20 WE-2B2A-02G-A115-20 WE-2B3A-02G-D2-20 WE-3C2-02G-A2-30 WE-3C2-02G-D2-30 WE-3C3-02G-A2-30
WE-3C3-02G-A115-30 WE-3C3-02G-D2-30 WE-3C4-02G-A2-30 WE-3C4-02G-A115-30 WE-3C4-02G-D2-30 WE-3C6-02G-A2-30
WE-3C6-02G-A115-30 WE-3C6-02G-D2-30 SRV-06G-3-D2-30 WE-2B2-03G-A2-30 WE-2B2A-02G-A230-3035 WE-2D2-02G-A115-30
WE-2D2-02G WE-2B3-02G WE-3C60-02G WE-3C6-02G WE-3C4-02G WE-3C2-02G
WE-2D2-03G WE-2B2-03G WE-2B2-02G WE-3C60-03G WE-3C6-03G WE-3C4-03G WE-3C2-03G WE-2B3-02G-D2-20 WE-2B2-02G-D2-20
MBR-02-P1-K-20 MBR-02-P2-K-20
Copyright ? 蘇州逐利機電有限公司 版權所有 備案號:蘇ICP備15047935號-1